Explosion proof radiation thermometer IR-CD
The IR-CD series is a pressure explosion proof radiation thermometer capable of measuring temperatures even in environments where flammable gases or liquid vapors are present and there is a risk of explosion.
It is certified as Ex db ⅡB T5 Gb by the Technology Association of Industrial Safety in Japan.
The lineup includes measurement temperature ranges of:
- 80 to 800°C (low to medium temperatures)
- 200 to 2000°C (medium temperatures)
- 500 to 3500°C (high temperatures).
Despite its explosion proof construction, it is compact and light-weight, and when combined with a sealing window, the measurement window becomes easier to clean.
Temperature measurement in environments where there is a risk of explosion
Features:
- Ex db II B T5 Gb certified by the Technology Association of Industrial Safety (type certification number: No. TC22717X)
- only connected via terminals (no connectors)
- explosion proof construction
- compact and lightweight
- easy maintenance of the measurement window when combined with sealing window
- can be operated from a non-hazardous location (outside of ATEX zone) when combined with a (optional) setting display.
- Type approval Numbers:
- TC17984: fixed focus type
- TC17952: focusable type
Specifications:
low & medium temperature
medium temperature
high temperature
Model:
IR-CDP
IR-CDI
IR-CDS
Measurement method (all models):
Narrowband radiation thermometer
Detecting element:
PbS
InGaAs
Si
Wavelength:
2 um
InGaAs
1.55 um
Response time:
20 ms (95%)
3 ms (95%)
3 ms (95%)
Measurement range () indicates distance factor:
80-250°C (50)
150-450°C (200)
200-800°C (200, 300)
200-1000°C (50)
300-1600°C (200, 300)
400-2000°C (measurement window diameter 10mm 200, 300)
500-2000°C (50)
600-3000°C (200, 300)
700-3500°C (measurement window diameter 10mm, 200, 300)
Accuracy:
Less than 500°C: +/- 3°C
500°C or higher: +/- 5°C
Less than 1000°C: +/- 5°C
1000-1500°C: +/- 0.5% of measured value
1500-2000°C: +/- 1% of measured value
2000°C or higher: +/- 2% of measured value
Less than 1000°C: +/- 5°C
1000-1500°C: +/- 0.5% of measured value
1500-2000°C: +/- 1% of measured value
2000°C or higher: +/- 2% of measured value
Repeatability:
Within 1°C
Within 0.2°C
Within 0.2°C
Temperature drift:
Below 500°C: 0.15°C/°C
500°C or above: 0.25°C/°C
0.1°C/°C or 0.015%/°C of the measured value, whichever is greater
0.1°C/°C or 0.015%/°C of the measured value, whichever is greater
Resolution:
1°C
0.5°C
0.5°C
Diameter of the lens aperture:
20mm
20mm, 10mm (with measurement window)
20mm, 10mm (with measurement window)
Diameter of the measurement area:
- focusable
- Measurement distance: 0.5m to infinity
- Measurement diameter = measurement distance / distance factor
- Distance factor: 50, 100, 200
- focusable
- Measurement distance: 0.5m to infinity
- Measurement diameter = measurement distance / distance factor
- Distance factor: 100, 200
- With measurement window diameter 10mm: distance factor 200,300
- focusable
- Measurement distance: 0.5m to infinity
- Measurement diameter = measurement distance / distance factor
- Distance factor: 100, 200
- With measurement window diameter 10mm: distance factor 200,300
Aiming (all models):
- Direct viewfinder (standard)
- optional 300 or 600mm macrolens
- optional laser aiming (without viewfinder)
Output signal (all models):
4-20mA DC, isolated output (impedance 500 ohms or less)
Power supply (all models):
24Vdc
Power consumption:
Maximum 10VA
Maximum 2.4VA
Maximum 2.4VA
External dimensions (all models):
W265xH175xD136mm
Weight (all models):
Approx. 7.5kg
Housing (all models):
Aluminium
Explosion proof symbol (all models):
ExdII BT5
Type certification number (all models):
No. C16741
Communication interface (optional) (all models):
RS-485 (option)
General remark:
Please allow a margin of about 1.5 times the measurement diameter to take into account the blurring of the optical axis, etc.
System setup & terminal connections
Note: click on the picture for a larger version
Dimensions
Note: click on the picture for a larger version
Model code IR-C (D) Z (X) (Y) (T) (Z) (A):
- (D): explosion proof type: fixed selection
- (X): measurement range type (see specification above):
- P: low to medium temperatures
- I: medium temperature
- S: high temperature
- (Y): distance factor:
- 0: 50
- 2: 200 (standard)
- 3: 300
- 7: diameter 10mm with distance factor 200 (only I and S types)
- 8: diameter 10mm with distance factor 300 (only I and S types)
- (T): terminal type connections: fixed selection
- (Z): (optional) external input/output:
- 5: 4-20mA DC output signal
- J: contact input
- K: contact output
- S: RS-485 communications
- (A): targeting:
- none: direct viewfinder (standard)
- 3: in combination with 300mm macro lens
- 6: in combination with 600mm macro lens
- L: laser projection (without direct viewfinder)
Please specify at ordering:
- what kind of object do you wish to measure?
- what is the distance to the object?
- is there any high temperature source like a heater involved?
- is there steam, frame dust or smoke?
- is the measurement through a window?
Symbol marking
Ex d II B T5:
- Ex: symbol indicating explosion proof construction
- d: symbol indicating explosion-protected construction
- II: for explosive gases in locations other than mines
- B: for atmospheres containing ethylene or gases of an equivalent hazard
- T5: temperature classification (more than 85°C to 100°C)
Representative gases:
Acetone, Ammonia, Carbon, Monoxide, Ethanol, Ethyl-Methyl-keton, Ethylene, Vinyl chloride Octane, Acetic acid, Acetic acid-Ethyl, Hyarocyanic acid, Toluene, Butane, Propane, Hexane, Benzene, Methanol, Methane, Gasoline, Tetra-hydro-furan