Chino IR-CD explosion proof radiation thermometer

Explosion proof radiation thermometer IR-CD

The IR-CD series is a pressure explosion proof radiation thermometer capable of measuring temperatures even in environments where flammable gases or liquid vapors are present and there is a risk of explosion.

It is certified as Ex db ⅡB T5 Gb by the Technology Association of Industrial Safety in Japan.

The lineup includes measurement temperature ranges of:

  • 80 to 800°C (low to medium temperatures)
  • 200 to 2000°C (medium temperatures)
  • 500 to 3500°C (high temperatures).

Despite its explosion proof construction, it is compact and light-weight, and when combined with a sealing window, the measurement window becomes easier to clean.

chino
Made in Japan
Chino IR-CD explosion proof infrared thermometer
IR-CD radiation thermometer
Exsplosion proof

Temperature measurement in environments where there is a risk of explosion

Features:
  • Ex db II B T5 Gb certified by the Technology Association of Industrial Safety (type certification number: No. TC22717X)
  • only connected via terminals (no connectors)
  • explosion proof construction
  • compact and lightweight
  • easy maintenance of the measurement window when combined with  sealing window
  • can be operated from a non-hazardous location (outside of ATEX zone) when combined with a (optional) setting display.
  • Type approval Numbers:
    • TC17984: fixed focus type
    • TC17952: focusable type

Specifications:

low & medium temperature
medium temperature
high temperature

Model:

IR-CDP

IR-CDI

IR-CDS

Measurement method (all models):

Narrowband radiation thermometer

Detecting element:

PbS

InGaAs

Si

Wavelength:

2 um

InGaAs

1.55 um

Response time:

20 ms (95%)

3 ms (95%)

3 ms (95%)

Measurement range () indicates distance factor:

80-250°C (50)
150-450°C (200)
200-800°C (200, 300)

200-1000°C (50)
300-1600°C (200, 300)
400-2000°C (measurement window diameter 10mm 200, 300)

500-2000°C (50)
600-3000°C (200, 300)
700-3500°C (measurement window diameter 10mm, 200, 300)

Accuracy:

Less than 500°C: +/- 3°C
500°C or higher: +/- 5°C

Less than 1000°C: +/- 5°C
1000-1500°C: +/- 0.5% of measured value
1500-2000°C: +/- 1% of measured value
2000°C or higher: +/- 2% of measured value

Less than 1000°C: +/- 5°C
1000-1500°C: +/- 0.5% of measured value
1500-2000°C: +/- 1% of measured value
2000°C or higher: +/- 2% of measured value

Repeatability:

Within 1°C

Within 0.2°C

Within 0.2°C

Temperature drift:

Below 500°C: 0.15°C/°C
500°C or above: 0.25°C/°C

0.1°C/°C or 0.015%/°C of the measured value, whichever is greater

0.1°C/°C or 0.015%/°C of the measured value, whichever is greater

Resolution:

1°C

0.5°C

0.5°C

Diameter of the lens aperture:

20mm

20mm, 10mm (with measurement window)

20mm, 10mm (with measurement window)

Diameter of the measurement area:

  • focusable
  • Measurement distance: 0.5m to infinity
  • Measurement diameter = measurement distance / distance factor
  • Distance factor: 50, 100, 200
  • focusable
  • Measurement distance: 0.5m to infinity
  • Measurement diameter = measurement distance / distance factor
  • Distance factor: 100, 200
  • With measurement window diameter 10mm: distance factor 200,300
  • focusable
  • Measurement distance: 0.5m to infinity
  • Measurement diameter = measurement distance / distance factor
  • Distance factor: 100, 200
  • With measurement window diameter 10mm: distance factor 200,300

Aiming (all models):

  • Direct viewfinder (standard)
  • optional 300 or 600mm macrolens
  • optional laser aiming (without viewfinder)

Output signal (all models):

4-20mA DC, isolated output (impedance 500 ohms or less)

Power supply (all models):

24Vdc

Power consumption:

Maximum 10VA

Maximum 2.4VA

Maximum 2.4VA

External dimensions (all models):

W265xH175xD136mm

Weight (all models):

Approx. 7.5kg

Housing (all models):

Aluminium

Explosion proof symbol (all models):

ExdII BT5

Type certification number (all models):

No. C16741

Communication interface (optional) (all models):

RS-485 (option)

General remark:

Please allow a margin of about 1.5 times the measurement diameter to take into account the blurring of the optical axis, etc.

System setup & terminal connections

Note: click on the picture for a larger version

Dimensions

Note: click on the picture for a larger version

Model code IR-C (D) Z (X) (Y) (T) (Z) (A):

  • (D): explosion proof type: fixed selection
  • (X): measurement range type (see specification above):
    • P: low to medium temperatures
    • I: medium temperature
    • S: high temperature
  • (Y): distance factor:
    • 0: 50
    • 2: 200 (standard)
    • 3: 300
    • 7: diameter 10mm with distance factor 200 (only I and S types)
    • 8: diameter 10mm with distance factor 300 (only I and S types)
  • (T): terminal type connections: fixed selection
  • (Z): (optional) external input/output:
    • 5: 4-20mA DC output signal
    • J: contact input
    • K: contact output
    • S: RS-485 communications 
  • (A): targeting:
    • none: direct viewfinder (standard)
    • 3: in combination with 300mm macro lens
    • 6: in combination with 600mm macro lens
    • L: laser projection (without direct viewfinder)
Please specify at ordering:
  • what kind of object do you wish to measure?
  • what is the distance to the object?
  • is there any high temperature source like a heater involved?
  • is there steam, frame dust or smoke?
  • is the measurement through a window?

Symbol marking

Ex d II B T5:

  • Ex: symbol indicating explosion proof construction
  • d: symbol indicating explosion-protected construction
  • II: for explosive gases in locations other than mines
  • B: for atmospheres containing ethylene or gases of an equivalent hazard
  • T5: temperature classification (more than 85°C to 100°C)

Representative gases:

Acetone, Ammonia, Carbon, Monoxide, Ethanol, Ethyl-Methyl-keton, Ethylene,  Vinyl chloride Octane, Acetic acid, Acetic acid-Ethyl, Hyarocyanic acid, Toluene, Butane, Propane, Hexane, Benzene, Methanol, Methane, Gasoline, Tetra-hydro-furan

Brochures & information