New version with more functions and possibilities
The new KR2 / KR3 series advanced paperless recorders are a major upgrade with regard to their KR2000 / KR3000 predecessors:
- all versions with color touchpanel operation
- various combinations of options available
- economically priced standard model with basic functionality
- direct .PDF file recording & support for FDA21 CFR part 11 and AMS 2750 / CQI-9 traceability for aerospace & automotive heat treatment
Configuration examples
Since there are an enormous amount of possible options and configurations, we first show you a few possible examples, in order to guide you through the forest of options towards to the solution that suits you best:
- KR2S*PS / KR3S: standard model (basic digital recording functionality)
- KR2D*PS / KR3D standard model with direct recording in .PDF file
- KR2S*PS—Z / KR3S—Z / KR2D*PS—Z / KR3D—Z: standard models with AMS2750F/CQI-9 Data Solution (add Z to model code) with functionality for:
- digital recording: .PDF file digital record (with KR2D*PS / KR3D model), with electronic signature
- binary file digital recording (data cannot be falsified)
- high input accuracy (traceable 16-point measurement input & sensor correction
- temperature sensor management (prevents sensors being used too long)
- system level restriction (limit operation to authorized personnel)
- KR2**PH / KR3**PH: FDA 21 CFR part 11 / AMS2750 & CQI-9 high performance model (non-tampering version)
- KR2D*PH / KR3D*PH: .PDF file recording FDA 21 CFR part 11 / AMS2750 & CQI-9 high performance model (non-tampering version)
General specifications
- input type thermocouple: K, E, J, T, R, S, B, N, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel2, U, L
- input type RTD: Pt50, Pt100, JPt100, Pt-Co (optional Nickel-100, Pt130, Pt25, Pt46, Cu10, Cu25, Cu53)
- input type DC voltage: mV or V
- number of inputs:
- KR2: 6 or 12 inputs
- KR3: 12, 24, 36 or 48 inputs
- fastest measurement cycle:
- KR2S*PS: approx. 100 msec/4 points & 1 sec/all points
- all other models: 1 sec/all points
- data recording cycle:
- KR2S**PS/KR2**PH 4 point input only:
- 100, 200, 500 msec
- 1 sec to 60 min
- all other models: 1 sec to 60 min.
- KR2S**PS/KR2**PH 4 point input only:
- display unit:
- KR2: 5.7″ color touchscreen operation
- KR3: 10.4″ color touchscreen operation
- external storage: USB flash drive (up to 8Gb) & CF-card (up to 8Gb). Note: high performance model uses SD-card (up to 32Gb) iso CF card.
- power supply: 100-240Vac
- dustproof & waterproof rating: IP54 (front)
- optional
- PDF chart automatic printing: KR2D/KR3D standard & high performance model with .PDF export version. (D stands for .PDF recording)
- FDA 21 CFR part 11 & AMS2750 / CQI-9 traceable electronic record of sensor and measurement channel calibration: KR2**PH/KR3**P high performance model. (P stands for non-tamperating traceable registration of changes to the recorder settings)
- MODBUS-RTU RS-485 interface
- MODBUS TCP ethernet interface (webserver for config, FTP & email generation for alarm & data reporting at specific time). (only with high performance model)
- RS-232 interface for bar code scanner (marker writing, group display switchover, batch operations depending on scanned barcode). (only with high performance model)
- extra digital inputs/outputs: see ordering code below
- custom graphic screen (you can use optional KR screen designer PC software to create your own graphic screen with measured values and send that to the recorder on CF/SD card)
- barcode reader specifications (barcode reader sold separately)
- barcode recipe specifications (barcode reader sold separately)
- historical viewer of past profiles (only with high performance model)
- carrying handle & feet
- built inside a rugged stainless steel housing in RAL color to your specification
- available certificates/documents:
- calibration
- validation
- installation qualification (IQ)
- operational qualification (OQ)
– Brochure KR2S*PS standard model
– Brochure KR3S standard model
– Brochure KR2S*PS / KR3S / KR2D*PS / KR3D standard model with AMS2750F / CQI-9 Data Solution add Z to model code
– Brochure KR2D*PS / KR3D standard model with .PDF file registration
– Brochure KR2**PH high performance model with ASM2750 / CQI-I & FDA21 CFR part 11 Data Solution
– Brochure KR3***H high performance model with AMS2750 / CQI-9 & FDA21 CFR part 11 Data Solution
– KR2S*PS / KR3S standard model instruction manual
– KR2D*PS / KR3D standard model with .PDF registration instruction manual
– KR2S*PS / KR3S / KR2D*PS / KR3D standard model heat treatment assistance specification instruction manual
– KR2**PH / KR3***H high performance model instruction manual
– KR2 / KR3 communication instruction manual (all models)
– KR2S*PS / KR3S / KR2D*PS / KR3D standard model heat treatment assistance communication instruction manual
Click here to request a quotation for the KR2/3 series recorders.
Chart paper versus digital recording
Conventional chart recorder on paper
Digital recording in .PDF & binary file
Disadvantages of chart paper recording:
- finding historical data takes a lot of time
- only 1 hardcopy on paper available: when paper is lost: no recording
- when not enough paper in recorder: no recording
- when pen in recorder is out of ink: no recording
- recording chart paper is expensive (and will become even more expensive)
- recording on papier is not very accurate (achieving +/- 1°C measurement accuracy on a 1200°C measurement range is difficult to achieve on paper registration)
- physical storage of recorded chart paper necessary over a long time
- transport of the recorder can influence the calibration of the measurements: for certain processes on-site calibration after transport is mandatory
Advantages of digital recording:
- historical data can be easily found back with just a few mouse clicks and even remotely with PC/tablet or Smartphone
- measurement data can be shared quickly & easily with co-workers for quick analysis process problems
- a .PDF digital file recording can be printed many times
- high accuracy of measurement data (+/- 0.1°C accuracy no problem at all)
- measurement data is stored digitally on CF/SD-card and/or on a (cloud-based) server: no or much less physical storage necessary for the data.
- measurements cannot be modified/falsified because they are stored in a binary file
- The .PDF file that is generated from the binary file can be digitally signed for data evidence
- transport of the recorder does not influence the accuracy of the measurements.
Digital process parameter recording leads to:
- reliable, dependable, accurate & transparent process parameter recording
- cost & time savings
- process optimalization
- quality improvement
External dimensions
Stainless steel housing
Can be built inside a rugged stainless steel housing in RAL color to your specification
Model codes KR2S*PS (S=standard model)
Model codes KR3S (S=standard model)
AMS2750F & CQI-9 data solution model
Special KR2S*PS / KR2D*PS / KR3S / KR3D standard model code with Z added for AMS2750F & CQI-9 data solution
Model codes KR2D*PS (D=direct recording in .PDF file model)
Model codes KR3D (D=direct recording in .PDF file model)
AMS2750F & CQI-9 data solution model
Special KR2S*PS / KR2D*PS / KR3S / KR3D standard model code with Z added for AMS2750F & CQI-9 data solution
Model codes KR2**PH high performance model
- Add D behind KR2 for direct recording in .PDF file model
- Add P before H (PH) for FDA21 CFR part 11 / AMS 2750 & CQI-9 model (non tampering model)
Model codes KR3***H high performance model
- Add D behind KR2 for direct recording in .PDF file model
- Add P before H (PH) for FDA21 CFR part 11 / AMS 2750 & CQI-9 model (non tampering model)